Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Chinese Journal of Laboratory Medicine ; (12): 725-731, 2023.
Article in Chinese | WPRIM | ID: wpr-995784

ABSTRACT

Objective:To establish a new strategy for rapid correction of the interference of chyle blood on hemoglobin (HGB) and related indexes by reticulocyte (RET) channel research parameters (HGB-O, MCHC-O) from automatic hematological analyzer.Methods:With the diagnostic experimental design, a total of 90 impatient samples were sequential picked from Fuwai Hospital, which had routine blood testing from June 1 to July 31, 2021. The selected samples were free of hemolysis, jaundice, chylo. The age of the patients was (49.2±5.7) years, with 47 males and 43 females. Three different contents(25, 50, 75 μl) of fat emulsion injection were used to replace plasma in equal amounts to prepare chyle blood samples with mild, medium and heavy degrees of average red blood cell hemoglobin concentration (MCHC). The research parameters (HGB-O, MCHC-O) obtained by the RET channel detection of the automatic blood analyzer were used as the corrected HGB and its related index values (RET method), and the original values (the detection values before adding fat emulsion) and the formula correction values were paired with t-test or Wilcoxon signed rank test, single factor analysis of variance or Kruskal-Wallis rank-sum test, Bland-Altman and correlation analysis to evaluate the correction effect of RET method.Results:There was no significant difference ( H=0.035, P=0.983; H=0.097, P=0.953; H=0.112, P=0.945) between the RET correction values of HGB (g/L) [104.0(83.8, 132.8), 109.0(87.78, 128.25), 104.0(87.8, 131.8)] and the original values [104.0(83.0, 133.0), 107.5(86.75, 129.25), 103.5(85.8, 131.3)] and the formula correction values [104.0(84.0, 133.8), 106.0(86.75, 131.25), 102.5(86.8, 131.3)] in the samples of chythemia with varying degrees of MCHC (g/L) elevation; meanwhile, the RET correction values [366.5(325.8, 341.5), 333.5(323.8, 340.0), 333.5(327.0, 341.25)] and the original values [336.0(324.8, 342.0), 333.0(323.5, 342.3), 332.0(326.75, 340.5)] and the formula correction values [333.5(323.5, 343.3), 331.0(321.0, 338.3), 329.5(325.25, 337.25)] were also not statistically significant ( H=0.049, P=0.976; H=3.149, P=0.207; H=0.883, P=0.643). The detection values of HGB and related indexes corrected by RET method were in good agreement with the original values [96.7% (29/30) of the points were within the 95% consistency limit], and the two were positively correlated (the correlation coefficients were all higher than 0.919, P<0.01). Conclusion:The RET method based on the research parameters of RET channel of automatic hematological analyzer can serve as a new strategy to correct the interference of chyle blood on the detection of HGB and related indexes.

2.
Chinese Journal of Microsurgery ; (6): 39-43, 2023.
Article in Chinese | WPRIM | ID: wpr-995473

ABSTRACT

Objective:To evaluate the efficacy of pedicled latissimus dorsi flaps in reconstruction of large soft tissue defects around elbow.Methods:From January 2012 to January 2022, 12 patients with large soft tissue defects around elbow received reconstructive surgery with pedicled latissimus dorsi flaps in Department of Microreconstructive Surgery, The First Affliliated Hospital of Xinjiang Medical University. Partial latissimus dorsi flaps were employed to reconstruct The soft tissue defects around the posterolateral side of elbow in 6 patients. Functional reconstruction of anteromedial soft tissue defect around elbow with functional latissimus dorsi myocutaneous flap combined with biceps muscle dynamic reconstruction was performed on other 6 patients. All patients were males and aged 18 to 57 years old, at 31.4 years old in average. Causes of injury: machine strangulation in 5 patients, traffic accident in 4 patients, machine crush in 2 patients, and fall from height in 1 patient. Injured sites: 5 patients had injury on right elbow and 7 on the left. The size of soft tissue defect ranged from 18.0 cm×10.0 cm to 51.0 cm×13.0 cm. The size of the flaps were at 30.0 cm×7.0 cm-55.0 cm×14.0 cm. The wounds at donor site were directly sutured. Follow-up included postoperative reviews via telephone, WeChat and visit to outpatient clinic. Mayo elbow performance scores(MEPS) at the last follow-up were recorded.Results:All 12 flaps survived, and all donor and recipient sites healed at stage I. The follow-ups lasted for 3 months to 2 years for all patients, with 18 months in average. Three months after operation, 1 patient underwent additional surgery for flap reduction due to a bloated flap and poor appearance. Six patients who received dynamic reconstruction myocutaneous flaps achieved grade IV in elbow flexion. Six patients with lateral elbow repaired with partial latissimus dorsi myocutaneous flap showed that the appearance of the flap was not bulky and had no effect on the flexion and extension function of the elbow joint. All flaps survived well at the last follow-up, with soft texture and colour close to the surrounding normal skin. All donor sites healed well, leaving only linear scars. Motion of all elbows was good. The MEPS at the final follow-up was(90.6±6.4), with 10 patients in excellent and 2 in good.Conclusion:According to the location of elbow joint soft tissue defect, different types of latissimus dorsi myocutaneous flaps are used for reconstruction, which can achieve good clinical results.

3.
Chinese Journal of Orthopaedic Trauma ; (12): 471-477, 2022.
Article in Chinese | WPRIM | ID: wpr-956543

ABSTRACT

Objective:To investigate the risk factors for axial deviation in the treatment of tibial defect susing Orthofix unilateral external fixator and proximal tibial osteotomy for bone transport.Methods:A retrospective study was performed to analyze the clinical data of 90 patients who had been treated for tibial bone defects by the Orthofix unilateral external fixator at Department of Microrepair and Reconstruction, The First Hospital Affiliated to Xinjiang Medical University from May 2012 to June 2019. There were 77 males and 13 females with a mean age of 41.2 years (from 17 to 63 years).The bone defects ranged from 4 to 13 cm in length. According to the Paley criteria for axial deviation, the 90 patients were divided into 2 groups: a deviation-free group with no axial deviation or an axial deviation ≤5° and a deviation group with an axial deviation>5°. The 2 groups were compared in terms of age, number of prior surgery, defect length, placement angle of Schanz screws, external fixation time, external fixation index and bending degree of Schanz screws at the last follow-up.The factors with P<0.05 were analyzed by multivariate logistic regression to find the risk factors for coronal axial deviation. Results:The 90 patients were followed up for an average of 23 months (from 12 to 40 months). The incidence of axial deviation in this cohort was 36.7% (33/90).The deviation group had a significantly larger number of prior surgery [5 (3, 6) times], a significantly longer defect length [8 (8, 9) cm], a significantly longer external fixation time [400.0 (341.8, 426.3) d], and a significantly greater bending degree of Schanz screws at the last follow-up [1.2° (0.4°, 3.5°)] than the deviation-free group [3 (2, 3) times, 6 (5, 8) cm, 340.8 (226.5, 422.8) d, and 0.8° (0.2°, 3.7°)] (all P<0.05). Multivariate logistic regression analysis showed that the number of prior surgery ( OR=2.581, 95% CI: 1.496-4.450, P=0.001) and the defect length ( OR=5.310, 95% CI: 1.952-14.442, P=0.001) were the risk factors for the axial deviation. Conclusion:In the treatment of tibial defect susing Orthofix unilateral external fixator and proximal tibial osteotomy for bone transport, the more prior surgeries and the longer a bone defect, the higher the risk for axial deviation.

4.
Chinese Journal of Microsurgery ; (6): 181-188, 2022.
Article in Chinese | WPRIM | ID: wpr-934192

ABSTRACT

Objective:To evaluate the effect and mechanism of bone regeneration in distraction osteogenesis zone after the repair of sciatic nerve in rats.Methods:Between January 2021 and August 2021, 60 healthy adult male Sprague-Dawley rats were divided randomly into 3 groups: Group A, B, and C. In groups B and C, right sciatic nerve transection and anastomosis were performed. Then after 8 and 12 weeks, the 3 groups were treated with extension external fixation (Ilizarov technique) of right femur osteotomy to make distraction osteogenesis model. Electrophysiological changes of peripheral nerves were monitored by electromyography (EMG) pre-and postoperatively in all the femoral lengthening rats. The formation of callus was examined by X-ray every week after operation. The rats were sacrificed on 2nd, 4th, 6th weeks after the bone transport operation. Four-point bending test and histological staining examination were carried out to determine the osteogenesis in the distracted area. SPSS 21.0 was used for statistical analysis. Data of measurement were expressed as (Mean±SD). A non-parametric test was used to assess the statistical difference between groups. Graphs were plotted by GraphPad Prism 8.0 and considered statistically significant when P<0.05. Results:The results of Sciatic nerve function index (SFI), Compound muscle action potential (CMAP) and Motor nerve conduction velocity (MNCV) in group A were better than the group B and group C in both of before and after the surgery. At the 2nd and 4th weeks of the consolidation stage, X-ray showed that bone formation in group B was superior to groups A and C; HE and Safranin O staining showed that local capillary and cartilage formation in group B was significantly more than in groups A and C; Immunohistochemical staining showed that the expression levels of Osteopontin(Opn) and Osteocalcin(Ocn) in the distraction area of group B were higher than that of groups A and C. At the 6th week of the consolidation stage, the four-point bending test showed that the bone quality of group B was better than groups A and C. The differences of the results between groups shown above had statistical significance ( P<0.05). Conclusion:Bone regeneration in the distraction area of the bone lengthening group with sciatic nerve injury was better than that of the bone lengthening group without a never injury. This might be in relation to the fact that a distractive osteogenesis caused the secondary injury to the repaired nerve. The electrophysiological results showed that periodic changes took place in the repaired sciatic nerve caused by the stretch of femoral lengthening, and the injurious changes of sciatic nerve would be gradually relieved in 6th week after surgery.

5.
Chinese Journal of Surgery ; (12): 786-792, 2018.
Article in Chinese | WPRIM | ID: wpr-807482

ABSTRACT

Objective@#To evaluate the effect of computer-assisted design based on three-dimensional reconstruction technique on the reduction accuracy of tibial and fibular fractures with Taylor external fixation.@*Methods@#A retrospective review was conducted on the clinical data of 69 patients who had tibia and fibula fractures treated with Taylor external fixation in department of orthopedic trauma of Tianjin Hospital from January 2016 to January 2018 to compare the residual deformity after fracture reduction between computer-assisted design method (experimental group) and the standard measurement method (control group). The frontal and lateral tibia and fibula X-ray of all the affected limbs were taken. In experimental group, all the patients took bilateral tibial CT tomography, and then DICOM format documents were input into the Mimics 17.1 software and got three-dimensional models of targeted bone and external fixation ring. After that the visual image matching was performed between external fixation ring three-dimensional reconstruction model and the standard model and also between the affected limb and the contralateral limb. Then the reduction trajectory plan of bone broken end and the position of external fixation ring were obtained. The STL files were input to Solid Works software and got the length of six rods to adjust the Taylor external fixation. In control group, the films were measured by Coreldraw X7 X-ray measurement software and the parameters were input in Taylor Spatial Frame system software. And then six calibrated threaded rods were adjusted according to the prescription of the software. Finally, all the patients took the X-ray films again to evaluate the degree of residual displacement. Skew distributional data are indicated with M(QR), and method of non-parameter was used to analyze variances between groups.@*Results@#All patients had better fracture reduction and achieved functional reset criteria. In the control group, the amount of displacement and angle residual aberration (improvement) in the frontal and lateral radiographs were 0.50(2.30)mm(90%), 0.00(0.85)mm(100%)and 0.00°(1.50°)(100%), 0.00°(0.00°)(100%), respectively. In the control group, the amount of displacement and angle residual aberration (improvement) in the frontal and lateral radiographs were 1.40(3.28)mm(69%), 2.15(4.27)mm(46%)and 1.15°(1.85°)(73%), 0.80°(2.10°)(67%). The positive and lateral angles and lateral displacements in the two groups were significantly different(P<0.05), but there was no statistically significant difference in positive displacement (P=0.099).@*Conclusion@#Both computer-assisted design method and the standard measurement method have satisfactory reduction effect, but computer-assisted design can accurately correct fracture deformity, which is good for fracture healing and functional recovery of affected limb.

6.
International Journal of Biomedical Engineering ; (6): 331-335, 2015.
Article in Chinese | WPRIM | ID: wpr-489564

ABSTRACT

Objective To analyze quantitatively the multiple parameters of iterative Dixon water-fat separation with echo asymmetric and least-squares estimation (IDEAL) MR imaging sequence, in order to realize safe, noninvasive and accurate observation of intervertebral disc degeneration, and to predict early degeneration in time, improve image quality, and to realize precision medical treatment by providing personalized examinations and optimized imaging protocols.Methods A total of 40 volunteers, 23 males and 17 females, with 20-84 years of age (mean (53.4±16.5) years), were participated in our study to accept lumbar spine MRI examination, including sequences of OSAG T2 FSE, OSAG T1 FSE, OAX T2 FSE, OSAG T2 FSE FS and OSAG IDEAL T2.Lumbar intervertebral disc degeneration was evaluated by Pfirrmann classification.The water signal fraction (WSF) of each disc was measured and calculated accurately with IDEAL in phase and IDEAL out phase images.The differences between Pfirrmann grade and WSF were analyzed statistically.The signal-to-noise ratio (SNR) measurements were carried out on equal size region of interest (ROI) from the same levels of vertebral body (L3) and background zone of T2 FSE FS and T2 IDEAL water image mid-sagittal planes, respectively, and the average value of vertebral body signal strength and the standard deviation of background signal were measured.SNRs of the two sequences were calculated, and the image qualities were compared statistically.Results Of all 200 lumbar discs that measured using Pfirrmann classification, 39 discs were classified as Pfirrmann grade Ⅰ, 42 as grade Ⅱ, 27 as grade Ⅲ, 53 as grade Ⅳ, and 39 as grade Ⅴ.The SNR of T2 FSE FS images was (11.42±6.17) dB, while that of the IDEAL water images was (20.63±9.44) dB, and there was a statistically significant difference between them (P<0.05).The WSF decreased along with the increase of Pfirrmann grade.The significant differences of WSF were found in all grades (P<0.05) except for the grade Ⅳ and Ⅴ (P>0.05).Conclusions The SNR of the IDEAL water images is significantly higher than that of T2 FSE FS images, which bring about better image quality.The WSF calculated based on the IDEAL in phase and IDEAL out phase images will make possible the quantitative, noninvasive and accurate analysis of lumbar disc degeneration, especially on the early stage of disc degeneration.

SELECTION OF CITATIONS
SEARCH DETAIL